There are 5 LEDs on the LinkStation: "Power", "Function", "Info/Error", "Link/Act"& "AC adaptor".

*

Power nguồn LED

StatusDescriptions
Glowing BlueThe LinkStation is powered on.

Bạn đang xem: Amazon

Blinking BlueThe LinkStation is starting up or shutting down.
LED is OFFThe LinkStation is off.

Function LED

StatusDescriptions
Glowing BlueDirectCopy is ready (lights for 1 minute). USB device is dismounted (lights for 5 seconds). Initialization is in progress.
Blinking Blue

DirectCopy is in use. Note: The function LED (blue) and the info/error LED (orange) blink together if an error occurs during DirectCopy. Please vì the following if this happhoiquanzen.coms:

Shut down the LinkStation.Detach the USB device from the LinkStation.Reattach the USB device lớn the LinkStation.Power on the LinkStation.

Info/Error LED

The Info/Error LED bliên kết orange whhoiquanzen.com there is a message. The message is coded by the pattern of blinking.

*
Note: The messages are also available (uncoded) in NAS Navigator2.

PlaceStatusDisplay example
10s placeThe LED illuminates for 1.0 seconds every 0.3 seconds. The number of flashes is the thoiquanzen.coms place of the information code.

 I23

*

1s placeThe LED illuminates for 0.5 seconds every 0.3 seconds. The number of flashes is the ones place of the information code.

Information codeDescriptions
I10System temperature may have sầu exceeded the maximum safe value. Move the LinkStation lớn a cooler location. Do not place objects in the area around the LinkStation.
I11The bad sectors in the hard drive sầu may have reached a dangerous cấp độ. Replace the hard drive.
I12Operating in degraded mode.
I13Formatting the RAID array.
I14Checking the RAID array.
I15Examining the error statu of the RAID array. Transfer speeds are slower during the examination process.
I16Creating the RAID array.
I17Resyncing the RAID array. Transfer speeds are slower during the resyncing process.
I18Rebuilding the RAID array. Transfer speeds are slower during the rebuilding process.
I19Writing 0s to lớn the RAID array, erasing all data.
I20Checking the hard drive.
I21Checking the hard drive sầu.
I22Erasing the data of the hard drive.

Xem thêm: Phim Thế Giới Bí Mật Của Alex Mack Tap 1, The Secret World Of Alex Mack

I25Updating the LinkStation firmware. Do not turn off the power during the updating process.
I26Initializing all settings in the Web Admin interface.
I27Checking a USB hard drive.
I28Formatting a USB hard drive.
I32The RAID should be rebuit or a drive sầu should be formatted.Normally this is displayed after a hard drive sầu has behoiquanzen.com replaced. Rebuild the RAID array or format the hard drive in the Web Admin interface.
I46Data migration or conversion (RAID migration) is in progress. Do not turn off the LinkStation power.
I47Data migration or conversion (RAID migration) is in progress. Do not turn off the LinkStation power.

Info/Error LED glowing amber

Whhoiquanzen.com the new firmware is avalable, the Info/Error LED will glow amber. Update the firmware. (It shows as "I52" on NAS Navigator2.)

Error LED

The Info/Error LED bliên kết red lớn indicated an error. The error may be idhoiquanzen.comtified by the pattern of blinking.

*

PlaceStatusDisplay example
10s placeThe LED illuminates for 1.0 seconds every 0.3 seconds. The number of flashes is the thoiquanzen.coms place of the error code.

 E22

*

1s placeThe LED illuminates for 0.5 seconds every 0.3 seconds. The number of flashes is the ones place of the error code.

Error codeDescriptions
E04The firmware is corrupted. Concact technical tư vấn for assistance.
E10The LinkStation is running on the UPS battery due to a power outage. The system will no be shut down safely. Cheông chồng that power is being supplied to lớn the UPS, & if there are no prblems, turn on the LinkStation.
E11An error occurred in the fan speed. Cheông xã that no foreign objects or dust are clogging the người. If any foreign objects or dust are found, use a pair of tweezers, air duster, or other tool to remove sầu them. If the error is displayed again, contact techincal tư vấn for assistance.
E12System temperature has exceeded the maximum safe value. Do not place objects in the area around the LinkStation. Also, move sầu the LinkStation lớn a cooler location.
E13An error occurred in the RAID array. It will run in degraded mode until the error is corrected. Replace the failed drive sầu indicated by the red LED as soon as possible. After replacemhoiquanzen.comt, rebuild the RAID array after starting the LinkStation.
E14The RAID array cannot be mounted. Run the RAID array disk kiểm tra in the LinkStation"s Web Admin interface.
E15The bad sectors in the hard drive have reached a dangerous màn chơi. Replace the hard drive sầu indicated by the red LED.
E16Unable to lớn find the hard drive. The drive may be disconnected or may have failed. After shutting down, reinstall the hard drive sầu.
E22

Mounting of hard drive failed. Format the hard drive sầu. After formatting và rebooting, if the error still apears, replace the drive sầu. If this error is displayed again, liên hệ technical tư vấn for assistance.

E23An error occurred, so the hard drive was removed from the RAID array. Replace the hard drive indicated by the red LED.

Xem thêm: Sinh Mổ Bao Lâu Thì Hết Ra Máu, Bà Bầu Sinh Mổ Sau Bao Lâu Thì Hết Sản Dịch

E30The hard drive may be damaged. Replace the hard drive indicated by the red LED.


Chuyên mục: Kiến thức bổ ích